Click on the OK button to save these values Immediately after this, the Optimus program tries to do an import. Hit Cancel Fresh out of the box, the scanner battery is probably not charged. Using the Metrologic scanner Turn the scanner on by pressing the power button The Main Menu displays Select 'Run Program' to begin scanning items This is the screen you will see when you are ready to scan With the scanner about a foot away from the barcode you want to scan, press the orange button in the middle of the scanner You will hear the scanner beep when it reads the barcode The SKU number is displayed and it is now requesting that you enter a quantity default is 1 Use the number keys on the scanner to adjust to the correct quantity and press the Enter key The scanner saves that data and moves back to the main scan screen ready for the next item to be scanned When you are finished scanning items press the ESC Escape key.

It should be displayed with SKUs in the A column and the quantities in the B column Now we need to save the file as a. For this example, I am Updating an existing count in Progress by selecting it and choosing the Update button- this step may take up to 5 minutes depending on the size of the count Click on the Imports option in the left column Click on the Add Import from Scanner or Spreadsheet button at the bottom and two windows will open - Retrieve Scanner Data And Resolve Scanner Data In the Retrieve Scanner Data window, Give the Import a Name in the field at the top of the window Click on the Browse button Navigate to the location where you saved the Data from the scanner.

You will see two screens And then the data Choose Go to Step 2 Items in the scan that are recognized items in your Inventory database will show as a Status of Verified. Items not recognized will show as a Status of Not Found. You will want to resolve any Not Found Items before continuing.

Not Found Items can be removed by selecting them and hitting the Delete button Hit Continue and the Import will show At this point, if you are done, you can Complete your Count by clicking on the Complete Count button OR if you have more adjustments to make click on the Exit Screen button.

You will notice on this screen that the physical count that I updated shows a new total number of Items. Related Content Title. URL Name. Chatter isn't enabled or the user doesn't have Chatter access. Follow Following Unfollow. Number of Views Don't see what you're looking for?

In Stock In stock and ready to ship! Manufacturer rebates, terms, conditions and expiration dates are subject to manufacturers printed forms. Update me with the latest news from Barcodes Inc.

MS OrbitCG offers innovative, elegant and affordable solution to retail applications and also safeguards long-term infrastructure commitments. Note that you will need to create an account to download any Honeywell software. Includes Ruby Verifone cable and manual. Dimensions LxWxH mm x mm x mm 4. Support Services Technical support and product service programs your organization needs ensuring seamless coverage for your Honeywell solutions.

User Guides and Ms Follow us on social media: Please download our Credit Application. Instock orders placed before 3: A sales representative will email you back next business day. Power supply is sold separately. Install the Optimus by plugging the cradle into your computer's USB port and then installing the proper drivers from the installation CD that come with the device. The SP Optimus S Portable Data Terminals are robust and versatile scanning devices designed to provide exceptional performance, while enduring the demands of everyday use.

OptimusS metrologic sp a compact batch portable data terminal designed for retail and light warehouse data collection applications, including inventory and stocking. The Startup menu enables users to take inventory. Demanding environment, which we encourage you should perform the scanner.

All models can synchronize as a batch device, with the option of BlueTooth communications for certain devices, allowing you to provide database updates as often as needed. However, PIN pads, 1. How to recover data from a hard drive stuck heads. Perfect for retail and light data applications, the Honeywell OptimusS is compact and powerful. In stock items metrologic sp the same business day if order is placed before 4, In order to get it to work, I need to manually inactivate items before uploading the data to the scanner.

This stylish batch portable data terminal PDT combines powerful features with easy-to-use software to get up and running in no time. The rugged exterior of the OptimusR makes the Optimus the ideal PDT for applications that take place in more rigorous environments.

Honeywell Safety and Productivity Solutions provides comprehensive solutions that enhance workplace safety and incident response, improve enterprise performance, and enable greater product design innovation. Get the scanner that fits your scanner that you!

In order to get up compatible hardware needed. The Startup menu enables the application program developer to specify which settings and prompts will be accessible upon the initialization of the Optimus unit. How do I install the Metrologic Inventory Scanner to take inventory. SP OptimusS is a great selection.